SERIES 2000 THICKNESS UNDER LINTEL

|
TYPICAL JAMB DETAIL

Concrete / Brick Fixing |

Steel RHS Fixing |

Steel RSJ Fixing |

Steel PFC Fixing |
POSITION OF OPEN DOOR
SERIES 2000 PROJECTION
|
 |
COUNTERWEIGHTS EACH SIDE
SINGLE DOOR

|

P = Pulley Headroom - min 430 for motorised
N = Room Width - add 25 for motorised
D = Room Depth |
COMMON COLUMN
BETWEEN 2 IDENTICAL DOORS |
 |

|

P = Pulley Headroom - min 430 for motorised
N = Room Width - add 35 for motorised
D = Room Depth |
Please note: The dimensions given in these graphs are intended as a general guide to installation requirements. In some cases a degree of variation can be allowed to suit special requirements, but the Renlita manufacturer must be consulted to determine the exact figure.
|